The ED-200 is an industrial Ethernet remote access router designed to simplify connection to sites using external PSTN, ISDN or GSM modems. Using this older technology, links can be created without the need to use the Internet which ensures improved security of the system.
A 4 port managed switch allows several industrial units (PLCs, HMIs or drives) to be connected locally. The unit can act either as a dial in or dial out PPP router to provide the remote connections. A simple port level IP firewall allows unwanted traffic to be filtered which can add to security, but can also ensure that unwanted traffic is not passed through the low bandwidth modem connection.
The wide power range, galvanic isolation on all ports and compact design make it ideal for easy installation in industrial applications.
Only industrial grade components are used which gives the ED-200 an MTBF of 558,000 hours and ensures a long service life. A wide operating temperature range of –25 to +65°C (–13 to +149°F) can be achieved with no moving parts.
The ED-200 has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial environments and rail trackside application.
| Status: | Active |
| Article number: | 3609-5010 |
| Ports: | 1 x 9-pin D-sub (male), RS-232 1 x 4-position detachable screw terminal, RS-422 4 x RJ-45, Ethernet TX |
| Description: | Ethernet Router |
| Warranty period: | 5 Years |
| PSTN: | ETSI TS103 021-1, ETSI TS103 021-2, ETSI TS103 021-3 |
| Service life, operating Operating: | 10 year |
| EN 61000-6-2: | Immunity industrial environments |
| EN 55024: | Immunity IT equipment |
| EN 61000-6-4: | Emission industrial environments |
| FCC part 15: | Class A |
| EN 50121-4: | Railway signalling and telecommunications apparatus |
| IEC 62236-4: | Railway signalling and telecommunications apparatus |
| EN 61000-4-2, ESD: | Enclosure contact, ± 6 kV Enclosure air, ± 8 kV |
| IEC 61000-4-3, RF field AM modulated: | Enclosure, 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz |
| ENV 50204, RF field 900 MHz: | Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
| EN 61000-4-4, fast transients: | Signal ports, ± 2 kV Power ports, ± 2 kV |
| EN 61000-4-5, surge: | Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line Power ports, ± 2 kV line to earth, ± 2 kV line to line |
| EN 61000-4-6, conducted RF immunity: | Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
| EN 61000-4-8, power frequency magnetic field: | Enclosure, 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
| EN 61000-4-9, pulsed magnetic field: | Enclosure, 300 A/m, 6.4 / 16 μs pulse |
| EN 61000-4-11, Voltage dips and interruption: | AC power ports 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction |
| EN 61000-4-16, Mains freq. 50 Hz: | Signal ports, 100 V 50 Hz line to earth |
| SS 436 15 03, Mains freq. 50 Hz: | Signal ports, 250 V 50 Hz line to line |
| EN 61000-4-29, voltage dips and interruption DC: | power ports 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & –20% below rated voltage |
| EN 55022, radiated RF emission: | Enclosure, class A |
| FCC part 15, radiated RF emission: | Enclosure, class A |
| EN 55022, conducted emission: | AC power ports, class A DC power ports, class A |
| FCC part 15, conducted emission: | AC power ports, class A |
| EN 60950-1, dielectric strength: | Signal port to other isolated ports, 2 kVrms 50 Hz 1 min Power port to other isolated ports, 3 kVrms 50 Hz 1 min, 2 kVrms 50 Hz 1 min (@ rated power <60 V) |
| Temperature, operating: | -25 to +65ºC (–13 to +149°F) |
| Temperature, storage: | -25 to +70ºC (–13 to +158°F) |
| Humidity, operating: | 5 to 95% relative humidity |
| Humidity, storage: | 5 to 95% relative humidity |
| Enclosure: | UL 94, PC / ABS, flammability class V-1 |
| Dimensions (W x H x D): | 55 x 100 x 132 mm |
| Weight: | 0.3 kg |
| Degree of protection: | IP 20 |
| Cooling: | Convection |
| Mounting: | Horizontal on 35 mm DIN-rail |
| IEC 60068-2-6, vibration: | Operating 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
| IEC-60068-2-27, shock: | Operating, 15 g, 11 ms |
| Rated voltage: | 12 to 48 VDC |
| Operating voltage: | 10 to 60 VDC |
| Rated current: | 360 mA @ 12 VDC |
| Rated frequency: | DC |
| Inrush current: | 0.51 A2s |
| Startup current: | 1 A |
| Polarity: | Reverse polarity protected |
| Redundant power input: | Yes |
| Isolation to : | Ethernet, RS-232, RS-422 |
| Connection: | Detachable screw terminal |
| Connector size: | 0.2 – 2.5 mm2 (AWG 24 – 12) |
| Shielded cable: | Not required |
| Electrical specification: | EIA RS-232 |
| Data rate: | 300 bit/s - 115.2 kbit/s |
| Data format: | 8 data bits, none parity, 1 stop bits |
| Protocol: | PPP |
| Transmission range: | 15 m / 49 ft |
| Isolation to : | Power and Ethernet |
| Galvanic connection to: | RS-422 |
| Connection: | 9-pin D-sub male (DTE) |
| Shielded cable: | Not required |
| Number of ports: | 1 |
| Electrical specification: | EIA RS-422 4-wire twisted pair |
| Data rate: | 300 bit/s to 115.2 kbit/s |
| Data format: | 8 data bits, none parity, 1 stop bit |
| Protocol: | PPP |
| Settings: | 120 Ω termination and failsafe biasing 680 Ω |
| Protection: | Installation Fault Tolerant (up to ±60 V) |
| Isolation: | to Power and Ethernet |
| Shielded cable: | Not required |
| Number of ports: | 1 |
| Electrical specification: | IEEE std 802.3. 2000 Edition |
| Duplex: | Full or half, manual or auto |
| Transmission range: | 100 m |
| Isolation to : | Power, RS-232 and RS-422 |
| Connection: | RJ-45 |
| Shielded cable: | Shielded cable is required if unit is used in harsh environment |
| Number of ports: | 4 |