HU | RO

TD-36 485

Other
TD-36 485

The TD-36 485 is an industrial modem designed to allow cost effective and simple remote access to legacy serial industrial equipment. The AT command driven modem is capable of synchronising with a wide range of traditional modem negotiation standards providing data rates up to 33.6 kbit/s over both PSTN and 2- or 4-wire lease line circuits.

Designed with remote unmanned industrial locations in mind the modem can operate in extremes of temperature and electromagnetic field. The complete galvanic separation of all interfaces ensures earth loops and transients do not interfere with communication. To keep visits to the site to a minimum a watchdog monitors the modem ensuring constant readiness, and remote re-configuration means that changes to settings can be handled without a site visit.

Firewalls are not an issue as data does not use the internet and with call back security it is impossible for either accidental or deliberate access to any equipment attached to the modem. To provide resilience a second line interface allows a PSTN connection to be established in the event of a lease line failure.

The modem is also simple to configure using the Westermo TD-tool software; standard commands can easily be entered and saved configurations downloaded. RS-232 connections can be made using screw connections as well as the standard D-sub. The modem is designed to be connected to devices with no ability to control dialling so special functions like data dialling and DTR dialling are provided to enable these devices to automatically establish connection.

Status: Active
Article number: 3618-0001
Ports: 1 x Public Switched Telephone Network (PSTN)
1 x Leased Line (LL)
1 x RS-422/485
1 x RS-232
Description: Industrial backup PSTN
and Leased Line Modem
Warranty period: 5 Years
PSTN: CS 03 Part 1, issue 9
FCC part 68, TIA-968-A
ETSI TS103 021-1, ETSI TS103 021-2, ETSI TS103 021-3
AS/ACIF S002, AS/ACIF S006
Service life, operating: Operating, 10 year
EN 55024: Immunity IT equipment
EN 55022: Emission IT equipment
EN 61000-6-1: Immunity residential environments
EN 61000-6-2: Immunity industrial environments
EN 61000-6-4: Emission industrial environments
FCC part 15: Class A
EN 50121-4: Railway signalling and telecommunications apparatus
IEC 62236-4: Railway signalling and telecommunications apparatus
EN 61000-4-2, ESD: Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV
IEC 61000-4-3, RF field AM modulated: Enclosure
20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM
ENV 50204, RF field 900 MHz: Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
EN 61000-4-4, fast transients: Signal ports, ± 2 kV
Power ports, ± 2 kV
EN 61000-4-5, surge: Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity: Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption: AC power ports
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
EN 61000-4-16, Mains freq. 50 Hz: Signal ports, 100 V 50 Hz line to earth
EN 61000-4-29, voltage dips and interruption: DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
EN 55022, radiated RF emission: Class A
FCC part 15, radiated RF emission : Class A
EN 55022, conducted emission: AC power ports, class B
PSTN, class B
DC power ports, class B
FCC part 15, conducted emission: AC power ports, class B
EN 60950-1, dielectric strength: Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)
Temperature, operating: –25 to +70°C (–13 to +158°F)
Temperature, storage: –40 to +70°C (–40 to +158°F)
Humidity, operating: 5 to 95% relative humidity non condensing
Humidity, storage: 5 to 95% relative humidity non condensing
Enclosure: UL 94, PC / ABS, flammability class V-1
Dimensions (W x H x D): 55 x 100 x 132 mm (2.16 x 3.93 x 5.19 in)
Weight: 0.36 kg
Degree of protection: IP 20
Cooling: Convection
Mounting: Horizontal on 35 mm DIN-rail
IEC 60068-2-6, vibration: Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
IEC-60068-2-27, shock: Operating, 15 g, 11 ms
Rated voltage: 20 to 250 VDC
24 to 240 VAC
Operating voltage: 18 to 300 VDC
22 to 264 VAC
Rated current: 125 mA @ 18 VDC
15 mA @ 110 VDC
8 mA @ 250 VDC
120 mA @ 22 VAC
35 mA @ 95 VAC
28 mA @ 240 VAC
Rated frequency: DC
Inrush current: 0.45 A²s
Startup current: 0.25 Apeak
Polarity: Polarity independent
Isolation to: All other ports 3 kVrms 50 Hz 1 min
Connection: Detachable screw terminal
Connector size: 0.2 – 2.5 mm² (AWG 24-12)
Shielded cable: Not required
Electrical specification: Opto isolated input
Input voltage range: 0 – 60 VDC
Input current: 5 mA @ 60 VDC
Input inactive: Uin < 2.5 V
Input active: Uin >5.0 V
Transmission range: Cable length ≤ 15 m
Connection: Detachable screw terminal (DCE)
Connector size: 0.2 – 2.5 mm² (AWG 24 – 12)
Isolation to: Power port, 3 kVrms 50 Hz 1 min
PSTN line, 2 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232, 2 kVrms 50 Hz 1 min
RS-485, 2 kVrms 50 Hz 1 min
I/O, output 2 kVrms 50 Hz 1 min
Shielded cable: Not required
Electrical specification: One change over contact
Switching voltage : Max 40 V AC/DC
Switching current : Max 500 mA AC/DC
Electrical endurance: 5 x 10^5 operations at 20 W / 20 VA Resistive load
Transmission range: Cable length ≤ 15 m
Connection: Detachable screw terminal (DCE)
Connector size: 0.2 – 2.5 mm² (AWG 24 – 12)
Isolation to: Power port, 3 kVrms 50 Hz 1 min
PSTN line 2, kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232 1.5, kVrms 50 Hz 1 min
RS-485 1.5, kVrms 50 Hz 1 min
I/O, input 2 kVrms 50 Hz 1 min
Shielded cable: Not required
@ 2013 Westermo | A Beijer Electronics group company | Legal Notice