The Wolverine DDW-222 allows effective Ethernet networks to be created over long distances (up to 15 km) at data rates up to 5.7 Mbit/s. The SHDSL technology makes it possible to reuse many types of pre-existing copper cables which can lead to considerable financial savings. Dependent on cable characteristics, distances up to 15 km (9.3 mi) can be achieved. The integrated RS-232 port allows legacy equipment to become part of an IP backbone network.

With its robust aluminium housing, the DDW-222 is designed for use in heavy duty industrial applications. The wide power range and I/O fault contact make it ideal for easy installation and monitoring in industrial applications. The Transient Blocking Unit (TBU) is acknowledged as the most effective form of protection against damaging noise spikes caused by lightning or high voltage equipment.

Only industrial grade components are used which gives the DDW-222 an MTBF of 700,000 hours and ensures a long service life. A wide operating temperature range of –40 to +70°C (–40 to +158°F) can be achieved without the need for moving parts or cooling holes in the case. The DDW-222 has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial environments.

For resilience, a ring of DDW-222s can be created using the Westermo FRNT protocol. This is configured using the simple web interface. For network management, SNMP provides an industry standard solution allowing the DDW-222 to be used as part of a large network.

Status: Active
Article number: 3642-0200
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232, 9-pin D-sub
Description: Ethernet extender with serial support
Warranty period: 5 Years
Hazardous locations: ATEX, EN 60079-0 and EN 60079-15. (Ex nA IIC T4 Gc) FM Approvals, Class 1 Div 2
SHDSL: NEMKO, ITU-T G.991.2
MTBF, operating: 700 000 hours @ 25°C, MIL-HDBK- 217F
EN 61000-6-2: Immunity industrial environments
EN 55024: Immunity IT equipment
EN 61000-6-4: Emission industrial environments
FCC part 15: Class A
EN 50121-4: Railway signalling and telecommunications apparatus
EN 61000-4-2, ESD: Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV
IEC 61000-4-3, RF field AM modulated: Enclosure
20 V/m 80% AM (1 kHz), 80 – 1000 MHz
10 V/m 80% AM (1 kHz), 1400 – 2100 MHz
5 V/m 80% AM (1 kHz), 2100 – 2500 MHz
1 V/m 80% AM (1 kHz), 2500 – 2700 MHz
EN 61000-4-4, fast transients: Signal ports, ± 2 kV
Power ports, ± 2 kV
EN 61000-4-5, surge: Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity: Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-8, power frequency magnetic field: Enclosure, 300 A/m
EN 61000-4-9, pulsed magnetic field: Enclosure, 300 A/m
EN 61000-4-16, Mains freq. 50 Hz: Signal ports, 100 V 50 Hz line to earth
SS 436 15 03, Mains freq. 50 Hz: Signal ports, 250 V 50 Hz line to line
EN 61000-4-29, voltage dips and interruption: DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
EN 55022, radiated RF emission: Enclosure, class A
FCC part 15, radiated RF emission: Class A
EN 55022, conducted emission: DC power ports, class B
Safety: EN 60950-1, IT equipment
EN 60950-1, dielectric strength: Signal port to other isolated ports, 1500 Vrms 50 Hz 1 min
Power port to other isolated ports, 1500 Vrms 50 Hz 1 min
Temperature, operating: –40 to +70°C (–40 to +158°F)
Temperature, storage: –40 to +70°C (–40 to +158°F)
Maximum surface temperature: 135ºC (temperature class T4)
Humidity, operating: 5 to 95% relative humidity
Humidity, storage: 5 to 95% relative humidity
Enclosure: UL 94, aluminium/zink, flammability class V-0
Dimensions (W x H x D): 134 x 100 x 122 mm (5.25 x 3.93 x 4.80 in)
Weight: 1.5 kg
Degree of protection: IP 40
Cooling: Convection
Mounting: Horizontal on 35 mm DIN-rail
IEC 60068-2-6, vibration: Operating, 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz
IEC-60068-2-27, shock: Operating, 15 g, 11 ms
Rated voltage: 20 to 48 VDC
Operating voltage: 16 to 60 VDC
Rated current: 300 mA @ 20 VDC
150 mA @ 48 VDC
Rated frequency: DC
Inrush current: 3.1 A2s
Startup current: 400 mA
Polarity: Reverse polarity protected
Redundant power input: Yes
Isolation to: Ethernet, SHDSL RS-232
Connection: Detachable screw terminal
Connector size: 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable: Not required
Electrical specification: IEEE std 802.3 2000 Edition
Data rate: 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex: Full or half
Transmission range: 100 m / 328 ft
Isolation to: Power, SHDSL RS-232
Connection: RJ-45
Shielded cable: Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located
close to rails. Number of ports
Electrical specification: ITU-T G.991.2 Annex B
Data rate: 192 kbit/s to 5696 kbit/s
Protocol: EFM according to IEEE 802.3-2004
Transmission range: According to ITU-T G.991.2 depending on the line quality
Protection: Overcurrent / overvoltage protection circuit and varistor
Isolation to: Power, Ethernet
Connection: Detachable screw terminal
Connector size: 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable: Not required
Number of ports: 2
Electrical specification: EIA RS-232
Data rate: 300 bit/s to 115.2 kbit/s
Data format: 7 or 8 data bits, odd, even or none parity, 1 or 2 stop bits
Protocol: Transparent, optimised by packing algorithm
Transmission range: 15 m / 49 ft
Isolation to: Power, SHDSL, Ethernet TX
Connection: 9-pin D-sub male (DTE)
Shielded cable: Not required
Number of ports: 1