HU | RO

ODW-730-F2

Other
ODW-730-F2

The ODW-730-F2 has been designed to allow the use of fibre optic cables on RS-422/485 networks. The design allows the use of a range of Westermo verified SFP (Small Form Pluggable) transceivers which can provide solutions with, for example, only a single fibre or distances up to 120 km. Both multidrop networks and redundant rings can be formed using a mixture of transceiver types.

This unit has been designed for industrial use where the requirement is for a long and reliable service life, in a harsh environment. To ensure this reliable operation we manufacture using the highest quality components.

The ODW-730 draws on Westermo’s many years of knowledge of serial protocols and can be used on both synchronous and asynchronous data streams. The switch selectable termination circuit saves the need for external terminating resistors.

Large ring networks can be created to provide network resilience to guarantee system functionality, even if a cable is damaged. The ring recovery time ensures that the network devices are not aware of the failure. The fault contact provides a method to communicate network failures.

Status: Active
Article number: 3651-0732
Ports: 1 x Detachable screw terminal, Status
1 x RS-232
1 x LC Duplex or LC Simplex, FX (Fibre)
Description: Ring / Multidrop Fibre Converter, RS-232
Warranty period: 5 years
Service life, operating: Operating, 10 years
EN 61000-6-1: Immunity residential environments
EN 61000-6-2: Immunity industrial environments
EN 61000-6-3: Emission residential environments
EN 61000-6-4: Emission industrial environments
EN 55022: Emission IT equipment, class A
EN 55024: Immunity IT equipment
FCC part 15: Class A
EN 50121-4: Railway signalling and telecommunications apparatus
IEC 62236-4: Railway signalling and telecommunications apparatus
EN 61000-4-2, ESD: Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV
IEC 61000-4-3, RF field AM modulated: 10 V/m 80% AM (1 kHz), 80 – 800 MHz
20 V/m 80% AM (1 kHz), 800 – 1000 MHz
20 V/m 80% AM (1 kHz), 1400 – 2700 MHz
ENV 50204, RF field 900 MHz: Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
EN 61000-4-4, fast transients: Signal ports, ± 2 kV
Power ports, ± 2 kV
EN 61000-4-5, surge: Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity: Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-9, pulsed magnetic field: Enclosure, 300 A/m, 6.4 / 16 μs pulse
EN 61000-4-11, Voltage dips and interruption: AC power ports, 10 & 5 000 ms, interruption, 200 ms,
40% residual voltage, 500 ms, 70% residual voltage
EN 61000-4-16, Mains freq. 50 Hz: Signal ports, 100 V 50 Hz line to earth
SS 436 15 03, Mains freq. 50 Hz: Signal ports, 250 V 50 Hz line to line
EN 55022, radiated RF emission: Enclosure, Class B
FCC part 15, radiated RF emission : bEnclosure, Class A
EN 55022, conducted emission: AC power ports, Class B
DC power ports, Class A
FCC part 15, conducted emission: AC power ports, Class B
Safety: UL/CSA/IEC/EN 60950-1, IT equipment
EN 60950-1, dielectric strength: Signal port to all other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power < 60V)
Temperature, operating: –40 to +60°C (–40 to +140°F)
Temperature, storage: –40 to +70°C (–40 to +158°F)
Humidity, operating: 5 to 95% relative humidity
Humidity, storage: 5 to 95% relative humidity
Enclosure: UL 94, PC / ABS, Flammability class V-1
Dimensions (W x H x D): 35 x 121 x 119 mm (1.37 x 4.76 x 4.68 in)
Weight: 0.26 kg
Degree of protection: IP 21
Cooling: Convection
Mounting: Horizontal on 35 mm DIN-rail
IEC 60068-2-6, vibration: Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
IEC-60068-2-27, shock: Operating, 15 g, 11 ms
Rated voltage: 12 to 48 VDC and 24 VAC
Operating voltage
Rated frequency: DC and 48 to 62 Hz
Inrush current: 0.2 A²s
Startup current: 1.0 Apeak
Polarity: Reverse polarity protected
Redundant power input: Yes
Isolation to: RS-232 and Status port
Connection: Detachable screw terminal
Connector size: 0.75 – 2.5 mm² (AWG 18 – 13). Connect the unit
using at least 18 AWG (0.75 mm2) wiring
Shielded cable: Not required
Electrical specification: EIA RS-485, 2-wire or 4-wire twisted pair
Data rate: 300 bit/s – 1.5 Mbit/s
Data format: 9 – 12 bits
Protocol: Start-bit followed by 8-11 bits
Retiming:
Turning time: One tbit
tbit = 1 / Baud rate (Baud rate in bit/s)
Transmission range: < 1200 m, depending on data rate and cable type (EIA RS-485)
Settings: 120 Ohm termination and failsafe biasing 680 Ohm
Protection: Installation Fault Tolerant (up to ±60 V)
Isolation to: Status and Power port
Connection: Detachable screw terminal
Connector size: 0.2 – 2.5 mm² (AWG 24 – 13)
Shielded cable: Not required